Solar Doctor · free Utah tool

Solar DoctorSolar Inverter Error Codes, explained in plain terms

Type the code or alert your solar app is showing. You'll see what it means, whether it's safe to wait or reset, and when to call. Then run a production check to see if your system is making what it should for its size and the month in Utah.

  • Enphase microinverters
  • SolarEdge
  • Tesla Powerwall
  • Utah production check
A solar monitoring app with one panel flagged red, a production curve drawing in, and an alert explained Today 31.4 kWh Array · 18 panels Microinverter not reportingUsually a communication drop,not a dead panel. Check the gatewayand Wi-Fi first. 1 panel needs attention · 1 offline

What does a solar inverter error code mean?

Solar inverter error codes tell you which part of the system stopped and why: the grid, the wiring, the inverter itself, or just the internet link to the app. Most codes fall into one of three lights. Grid and communication alerts usually clear on their own. Temperature and voltage codes may need a reset. Isolation, ground-fault and arc-fault codes mean stop and call a licensed electrician. Never reset those.

Green · wait it outGrid outage, grid frequency or voltage blips, app offline, snow cover, dawn/dusk low voltage.
Amber · reset or watchNot reporting, over-temperature, overloaded battery, breaker open. Call if it repeats.
Red · stop and callIsolation or ground fault, DC Resistance Low, arc fault, inverter fault light. Don't reset.
The Solar Doctor

Look up a solar error code or check your production

Search 38 common solar inverter error codes and alerts by code (03x9A, 18xC), by alert name (Grid Gone, Powerwall Overloaded) or by what you see (red light, gray panel). Or switch tabs and compare last month's kWh with what a healthy Utah system makes.

Code meanings come from Enphase and Tesla manuals and published SolarEdge troubleshooting guides. Your inverter's manual and app have the final word. For your safety, don't open inverters, disconnects or the panel, and don't go on the roof.

Where in Utah?
Which way do most panels face?
Shade on the roof
System age
—of expected
Enter last month's kWh

A healthy 8 kW system on the Wasatch Front makes roughly the range shown below for the month you pick.

    Enphase

    Enphase error codes and events, decoded

    Enphase systems report through the IQ Gateway (older systems call it the Envoy) to the Enphase app. Each panel's microinverter reports on its own, so one bad unit rarely takes the whole system down. Its solar inverter error codes show up as named events rather than numbers.

    Event in the appWhat it meansWhat to do
    Microinverter not reportingA microinverter stopped talking to the gateway over the house wiring. It may still be producing.Check that the gateway has power. Occasional drops are normal. If it lasts more than a day or hits many panels, call.
    IQ Gateway / Envoy not reportingThe gateway can't reach Enphase's servers. Production usually continues.Restart your modem and router, then the gateway. New router or Wi-Fi password? Reconnect it.
    Grid GoneUtility power is absent or out of spec, so microinverters shut off by design.Normal during outages. Check the solar breaker is on. If one branch keeps showing it, call.
    AC Voltage / Frequency Out of RangeGrid voltage or frequency left the allowed window (ACVOOR / ACFOOR).Usually clears itself. If it repeats daily, an electrician checks the wiring and the utility transformer.
    DC Resistance Low – Power OffInsulation from the panel wiring to ground dropped too low: a damaged module, wire or connector, or moisture. That microinverter stops producing.Call. The cause must be fixed, then the fault is cleared through Enphase's installer platform.
    GFI tripped (older models)The microinverter saw more than 1 A of DC ground-fault current.Call. Water in a connector or a pinched lead is common. Don't touch the array.
    Critical / Over TemperatureThe microinverter is running hot and has reduced output.No action unless it persists on hot days. Then call.
    DC Too LowPanel voltage is below what the microinverter needs.Normal at dawn, dusk and under snow. During bright daylight, call.

    Sources: Enphase Envoy troubleshooting guide · Enphase IQ8 manual: status LEDs. More on Enphase solar in Utah.

    SolarEdge

    SolarEdge error codes: which ones are safe to reset

    SolarEdge inverters show codes on the screen or in the mySolarEdge app, often in a format like 18xC or 03x9A. The first rule with any solar inverter error code: write it down, and take a photo of the screen, before you touch anything.

    CodeMeaningSafe to reset?
    03x9A · 18x86 · 33xIsolation fault: current leaking from the DC wiring to groundNo. Call a licensed electrician.
    18x3DGround current faultNo. Call.
    18xCArc fault detected, a possible sparking hazardNever. Turn the system off at the inverter and call.
    18xB5 · 18xB7Internal overvoltage in HD-Wave inverters, often failed capacitorsNo. Usually a warranty part or inverter replacement.
    18x75Thermal shutdown: the inverter got too hotAfter it cools down. Call if it repeats.
    18x37 · 18x38Grid voltage too low / too highYes, once the grid stabilizes. Call if it keeps happening.

    Sources: GreenLancer SolarEdge troubleshooting · Solar Permit Solutions code guide. For repair-or-replace decisions, see solar inverter repair.

    Tesla

    Tesla Powerwall alerts and what to do

    Tesla shows alerts in the Tesla app rather than numbered codes. Most need nothing from you. A few mean book a service visit.

    AlertWhat it meansWhat to do
    Grid OutageYour home is running on Powerwall.Turn off big loads to stretch backup.
    Low Energy While Off-GridThe battery is running low during an outage.Cut power use right away.
    Powerwall OverloadedToo much load at once during backup.Turn off high-power items. It retries within 2 minutes.
    Breaker Open · Side Switch OffThe Powerwall breaker or its side switch is off.Turn it back on (left side on Powerwall 3) if you didn't mean to switch it off.
    Waiting for Solar / User InputThe battery emptied off-grid and is waiting to restart.Reduce load, then restart with the switch once the sun is up.
    Solar Production LimitedSolar output is being restricted by a fault.Book a site visit.
    Powerwall Disabled · flashing red lightInverter fault. The unit needs service.Turn off the enable switch and call a Tesla Certified Installer.

    Sources: Tesla Powerwall system alerts · Powerwall 3 owner's manual: troubleshooting. Elite is a Tesla Certified Installer. See Powerwall installation in Utah.

    Status lights

    What the blinking lights mean

    No app access? The lights on the equipment show the same solar inverter error codes in simpler form. Look from the ground or the garage only.

    Enphase · flashing greenNormal. Grid fine, talking to the gateway.
    Enphase · flashing orangeProducing, but not talking to the gateway.
    Enphase · flashing redGrid absent or out of spec. Normal in an outage.
    Enphase · solid redDC Resistance Low – Power Off. Call.
    Powerwall 3 · solid whiteNormal operation.
    Powerwall 3 · flashing whiteIdle. It may go to sleep.
    Powerwall 3 · flashing redInverter fault. Book service.
    SolarEdge · red LEDFault. Read the code on the screen or app.
    Production

    Is my solar system working? Utah solar production by month

    The surest way to know your system is healthy is to compare a month's kWh with what that size of system should make here. A well-placed south-facing system on the Wasatch Front makes about 1,450 kWh per kW each year, but winter months make less than half of July.

    Expected monthly production for an 8 kW south-facing system on the Wasatch Front
    Expected kWh for an 8 kW south-facing system on the Wasatch Front. Monthly shape from NREL PVWatts solar data for Salt Lake City, scaled to 1,450 kWh/kW per year.
    MonthPer kW6 kW system8 kW system10 kW system

    Running well below these numbers for two months in a row, outside of snow season, is worth a diagnosis. Thinking about adding panels instead? Try the instant solar estimate.

    Utah factors

    What lowers solar output in Utah

    • Snow on the panelsSnow can cut production to near zero for a day or two. It usually slides off on the first sunny afternoon. Don't climb up to clear it.
    • Short winter daysDecember makes about a third of July, so a low winter bill credit isn't a fault.
    • One failed microinverterShows as a gray or 0 W panel. Each one costs roughly 1/N of output on an N-panel system.
    • New shadeA tree that grew a few feet, or a neighbor's addition, can take 10–30% off a string.
    • Monitoring offlineThe app shows zero while the panels keep producing. Check your utility bill's "received" kWh to confirm.
    • AgePanels typically lose about 0.5% a year, so a 10-year-old system makes about 5% less than new.

    Stop and call right away if:

    • You smell burning, or see scorch marks or melted plastic near the inverter, disconnect or panel
    • You see an arc-fault, isolation or ground-fault code (SolarEdge 18xC, 03x9A, Enphase DC Resistance Low)
    • A breaker trips again right after you reset it
    • The Powerwall light is flashing red
    Stuck on a code?

    Send us the code and we'll tell you what it means for your system

    Tap "Use this code in my message" on any result, or run the production check, and it fills in below. Rebecca calls back within about one business day with a straight answer. Sometimes it's a fix you can do yourself.

    • Enphase, SolarEdge, Tesla and Sigenergy
    • Systems we didn't install are welcome
    • Warranty claims handled for you
    Warranty & service

    Who fixes it, and does the warranty still apply?

    Equipment warranties come from the manufacturer, not your installer. Enphase microinverters typically carry 25-year warranties, SolarEdge inverters 12 years and Tesla Powerwall 10 years. Those still apply even if the company that installed your system is gone. The workmanship warranty usually isn't, because it came from the installer. Freedom Forever, for example, filed for Chapter 11 in April 2026.

    Elite services solar and battery systems we didn't install. A diagnostic visit is $325 for the first hour, then $150 per hour plus parts. We file the manufacturer warranty claim for you when the part is covered. Our solar panel repair page covers repair costs and what to do when your installer is gone.

    Elite Electric electrician servicing a Tesla Powerwall in Draper, Utah after reading the solar inverter error codes
    Powerwall service in Draper, UT
    ★★★★★
    "Tyler and team always are very responsive to help even with warranty issues. He came next day to help fix an issue."
    Katy Westenskow · Google review
    ★★★★★
    "Had some questions about my solar system and he took him time to answer everything."
    Blake Hiatt · Google review
    ★★★★★
    "Cole was great to work with and spec'd out a system to meet our needs. Install went smoothly."
    Kyle Gisler · Google review

    5.0★ from 58 Google reviews · A+ rating on BBB · Read our Google reviews

    Questions

    Solar inverter error codes: common questions from Utah owners

    What does "microinverter not reporting" mean on Enphase?

    One or more microinverters stopped sending data to the IQ Gateway. Often the panel is still producing and only the communication dropped. Check the gateway's power and your internet first. If it lasts more than a day or affects several panels, have it diagnosed.

    Is it safe to reset my solar inverter?

    For grid voltage, grid frequency and over-temperature codes, usually yes, once conditions return to normal. Never reset after isolation, ground-fault or arc-fault codes such as SolarEdge 03x9A, 18x3D or 18xC, or Enphase DC Resistance Low. Those need a licensed electrician.

    What does SolarEdge error 18xC mean?

    18xC is an arc-fault detection code, which means the inverter sensed possible sparking in the DC wiring. Don't reset it. Shut the system off at the inverter and call a licensed electrician.

    What does solid red mean on an Enphase microinverter?

    A solid red status light means a DC Resistance Low – Power Off condition. The insulation between the panel wiring and ground has dropped, so that unit stopped producing until the cause is fixed and the fault is cleared.

    How do I know if my solar system is working?

    Compare last month's kWh with the expected range for your system size and month. A south-facing Wasatch Front system makes about 1,450 kWh per kW a year, about 173 per kW in July and 59 in December. The production check above does the math for you.

    Why is my solar production so low in winter in Utah?

    Short days, a low sun and snow cover. December typically makes about a third of July's output on the Wasatch Front, and snow-covered panels make almost nothing until it slides off.

    What does "Solar Production Limited" mean on a Tesla Powerwall?

    Tesla shows this banner when solar output is being restricted by a problem in the system. Tesla's guidance is to contact your installer for a site visit.

    My installer went out of business. Who can fix my system?

    Any licensed solar electrician can, and manufacturer warranties still apply. Elite services systems we didn't install, starting with a $325 first-hour diagnostic, and handles the warranty claim when a part is covered.

    Get a diagnosis

    Send us the code. We'll tell you what it takes.

    Paste the solar inverter error code you found or your production check, add a screenshot of your app if you can, and we'll call with a straight answer. Sometimes it's a five-minute fix you can do yourself.

    • We service systems we didn't install: Enphase, SolarEdge, Tesla, Sigenergy and more
    • Rebecca calls back within about one business day
    • Diagnostic visit $325 first hour, warranty claims handled
    • Tesla Certified Installer · DOPL-licensed Master Electrician on staff
    Call our Sandy, UT office · (801) 928-7219

    Other free tools: home battery backup calculator · panel upgrade calculator · Rocky Mountain Power bill calculator

    CallGet a diagnosis